Pressure coefficient

The pressure coefficient is a dimensionless number which describes the relative pressures throughout a flow field in fluid dynamics. The pressure coefficient is used in aerodynamics and hydrodynamics. Every point in a fluid flow field has its own unique pressure coefficient, .

In many situations in aerodynamics and hydrodynamics, the pressure coefficient at a point near a body is independent of body size. Consequently an engineering model can be tested in a wind tunnel or water tunnel, pressure coefficients can be determined at critical locations around the model, and these pressure coefficients can be used with confidence to predict the fluid pressure at those critical locations around a full-size aircraft or boat.

Definition

The pressure coefficient is a parameter for studying the flow of incompressible fluids such as water, and also the low-speed flow of compressible fluids such as air. The relationship between the dimensionless coefficient and the dimensional numbers is [1] [2]

where:

is the pressure at the point at which pressure coefficient is being evaluated
is the pressure in the freestream (i.e. remote from any disturbance)
is the freestream fluid density (Air at sea level and 15 °C is 1.225 )
is the freestream velocity of the fluid, or the velocity of the body through the fluid

Profile pressure coefficient

Main article: Incompressible flow

Using Bernoulli's Equation, the pressure coefficient can be further simplified for potential flows (inviscid, and steady):[3]

where u is the flow speed at the point at which pressure coefficient is being evaluated, and Ma is the Mach number: the flow speed is negligible in comparison with the sound speed. For a case of an incompressible but viscous fluid, this represents the profile pressure coefficient, sinceitis associated to the pressure hydrodynamic forces rather than to the viscous ones.

This relationship is valid for the flow of incompressible fluids where variations in speed and pressure are sufficiently small that variations in fluid density can be neglected. This is a reasonable assumption when the Mach Number is less than about 0.3.

of minus one is significant in the design of gliders because this indicates a perfect location for a "Total energy" port for supply of signal pressure to the Variometer, a special Vertical Speed Indicator which reacts to vertical movements of the atmosphere but does not react to vertical maneuvering of the glider.

In the fluid flow field around a body there will be points having positive pressure coefficients up to one, and negative pressure coefficients including coefficients less than minus one, but nowhere will the coefficient exceed plus one because the highest pressure that can be achieved is the stagnation pressure.

Compressible flow

Main article: Compressible flow

In the flow of compressible fluids such as air, and particularly the high-speed flow of compressible fluids, (the dynamic pressure) is no longer an accurate measure of the difference between stagnation pressure and static pressure. Also, the familiar relationship that stagnation pressure is equal to total pressure does not always hold true. (It is always true in isentropic flow but the presence of shock waves can cause the flow to depart from isentropic.) As a result, pressure coefficients can be greater than one in compressible flow.[4]

Pressure distribution

An airfoil at a given angle of attack will have what is called a pressure distribution. This pressure distribution is simply the pressure at all points around an airfoil. Typically, graphs of these distributions are drawn so that negative numbers are higher on the graph, as the for the upper surface of the airfoil will usually be farther below zero and will hence be the top line on the graph.

Relationship with aerodynamic coefficients

All the three aerodynamic coefficients are integrals of the pressure coefficient curve along the chord. The coefficient of lift for a two-dimensional airfoil section with strictly horizontal surfaces can be calculated from the coefficient of pressure distribution by integration, or calculating the area between the lines on the distribution. This expression is not suitable for direct numeric integration using the panel method of lift approximation, as it does not take into account the direction of pressure-induced lift.

where:

is pressure coefficient on the lower surface
is pressure coefficient on the upper surface
is the leading edge location
is the trailing edge location

When the lower surface is higher (more negative) on the distribution it counts as a negative area as this will be producing down force rather than lift.

See also

References

  1. Clancy, L.J., Aerodynamics, section 3.6
  2. Abbott and Von Doenhoff, Theory of Wing Sections, equation 2.24
  3. Anderson, John D. Fundamentals of Aerodynamics. 4th ed. New York: McGraw Hill, 2007. 219.
  4. http://thesis.library.caltech.edu/608/1/Scherer_lr_1950.pdf
This article is issued from Wikipedia - version of the 10/21/2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.