M squared

In laser science, the parameter M2, also known as the beam quality factor, represents the degree of variation of a beam from an ideal Gaussian beam.[1] It is calculated from the ratio of the beam parameter product (BPP) of the beam to that of a Gaussian beam with the same wavelength. It relates the beam divergence of a laser beam to the minimum focussed spot size that can be achieved. For a single mode TEM00 (Gaussian) laser beam, M2 is exactly one.

The M2 value for a laser beam is widely used in the laser industry as a specification, and its method of measurement is regulated as an ISO Standard.[2]

Utility

M2 is useful because it reflects how well a collimated laser beam can be focused to a small spot, or how well a divergent laser source can be collimated. It is a better guide to beam quality than Gaussian appearance because there are many cases in which a beam can look Gaussian, yet have an M2 value far from unity.[1] Likewise, a beam intensity profile can appear very "un-Gaussian", yet have an M2 value close to unity.

The value of M2 is determined by measuring D4σ or "second moment" width. Unlike the beam parameter product, M2 is unitless and does not vary with wavelength.

Multi-mode beam propagation

Real laser beams are often non-Gaussian, being multi-mode or mixed-mode. Multi-mode beam propagation is often modeled by considering a so-called "embedded" Gaussian, whose beam waist is M times smaller than that of the multimode beam. The diameter of the multimode beam is then M times that of the embedded Gaussian beam everywhere, and the divergence is M times greater, but the wavefront curvature is the same. The multimode beam has M2 times the beam area but 1/M2 less beam intensity than the embedded beam. This holds true for any given optical system, and thus the minimum (focussed) spot size or beam waist of a multi-mode laser beam is M times the embedded Gaussian beam waist.

Applications

The quality of a beam is important for many applications. In fiber-optic communications beams with an M2 close to 1 are required for coupling to single-mode optical fiber. Laser machining and laser welding shops care a lot about the M2 parameter of their lasers because the beams will focus to an area that is M2 times larger than that of a Gaussian beam with the same wavelength; in other words, the fluence scales as 1/M2.

Generally, M2 increases as a laser's output power increases. It is difficult to obtain excellent beam quality and high average power at the same time due to thermal lensing in the laser gain medium.

See also

References

  1. 1 2 Siegman,, A. E. (October 1997). "How to (Maybe) Measure Laser Beam Quality" (PDF). Archived from the original (pdf) on June 4, 2011. Retrieved Feb 8, 2009. Tutorial presentation at the Optical Society of America Annual Meeting, Long Beach, California
  2. "Lasers and laser-related equipment – Test methods for laser beam widths, divergence angles and beam propagation ratios". ISO Standard. 11146. 2005.
This article is issued from Wikipedia - version of the 9/7/2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.